High Acuity Nursing 6th Edition by Kathleen Dorman Wagner
High Acuity Nursing 6th Edition by Kathleen Dorman Wagner
$2.99
Chapter 07 High Acuity Nursing 6th Edition by Kathleen Dorman Wagner
Complete Chapter Questions With Answers
Sample Questions Are Posted Below
Question 1
Type: MCSA
The nurse is preparing to use a patient’s pulmonary artery catheter to obtain hemodynamic measurements. Which nursing action is indicated?
Correct Answer: 1
Rationale 1: The phlebostatic axis approximates the level of the right atrium and is considered to represent the level of the catheter tip.
Rationale 2: Trendelenburg position or the head down position may be used during insertion of the catheter to make visualization of the jugular approach easier. However, supine is the recommended position for hemodynamic readings.
Rationale 3: Injectate should be iced or room temperature but not warmed.
Rationale 4: The traditional method of thermodilution cardiac output uses a 10mL bolus of injectate.
Global Rationale:
Cognitive Level: Applying
Client Need: Physiological Integrity
Client Need Sub: Physiological Adaptation
Nursing/Integrated Concepts: Nursing Process: Implementation
Learning Outcome: 7-4
Question 2
Type: MCSA
The preceptor nurse is assisting a newly hired nurse with completion of hemodynamic assessment using a pulmonary artery catheter. Which action would require the preceptor to intervene?
Correct Answer: 2
Rationale 1: In order to overcome arterial pressure and prevent blood from backing up into the pressure tubing, the pressure bag placed around the flush solution should be inflated to 300 mm Hg.
Rationale 2: The proximal injectate port is the primary port used for obtaining cardiac output via boluses of iced or room temperature normal saline. Because of the risk of inadvertent bolus of potent medications, neither vasopressor nor vasodilators should be administered through the same port used for obtaining cardiac output. It would be safer to infuse vasoactive drugs through the proximal infusion port.
Rationale 3: The distal port is the designated port for continuous monitoring of the pulmonary artery pressure and for obtaining the pulmonary artery wedge pressure.
Rationale 4: Either iced or room temperature normal saline can effectively be used to obtain accurate cardiac output measurements.
Global Rationale:
Cognitive Level: Analyzing
Client Need: Physiological Integrity
Client Need Sub: Reduction of Risk Potential
Nursing/Integrated Concepts: Nursing Process: Evaluation
Learning Outcome: 7-3
Question 3
Type: MCSA
While caring for a patient being hemodynamically monitored the nurse notices that the systemic vascular resistance has risen to 1,800 dynes/sec/cm5, whereas the patient’s cardiac output remains at 6.0 liters per minute. What would the nurse expect the patient’s blood pressure to be?
Correct Answer: 1
Rationale 1: Systemic vascular resistance or afterload is the pressure the heart pumps against to get volume out to the lungs or the body. If that pressure is increased, but volume, measured by cardiac output stays the same, it means that the heart is working harder to get volume out and the blood pressure will go up.
Rationale 2: Increasing systemic vascular resistance with no change in cardiac output does indicate a change in blood pressure.
Rationale 3: Since the heart is working harder, blood pressure will not decrease immediately.
Rationale 4: The blood pressure would increase initially in response to the increased workload. If treatment is not initiated, the heart will eventually tire, and a decrease in blood pressure could be expected.
Global Rationale:
Cognitive Level: Analyzing
Client Need: Physiological Integrity
Client Need Sub: Physiological Adaptation
Nursing/Integrated Concepts: Nursing Process: Assessment
Learning Outcome: 7-7
Question 4
Type: MCSA
The nurse is reviewing the results of a patient’s cardiac output curve and notes that the size of the curve is small. Which of the following does this finding indicate?
Correct Answer: 4
Rationale 1: A large curve indicates a slow return to baseline temperature and, therefore, a low cardiac output.
Rationale 2: The size of the curve does not indicate poor injection technique.
Rationale 3: A small cardiac output curve does not indicate incorrect placement of the catheter.
Rationale 4: A small curve indicates a rapid return of the blood to its baseline temperature and, therefore, a high cardiac output.
Global Rationale:
Cognitive Level: Analyzing
Client Need: Physiological Integrity
Client Need Sub: Physiological Adaptation
Nursing/Integrated Concepts: Nursing Process: Assessment
Learning Outcome: 7-3
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$100.00 Original price was: $100.00.$75.00Current price is: $75.00.
$39.99 Original price was: $39.99.$19.99Current price is: $19.99.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
511 SW 10th Ave 1206, Portland, OR, United States