Chapter 16 Medical Surgical Nursing 2nd Edition By Osborn Wraa Watson
Complete Chapter Questions With Answers
Sample Questions Are Posted Below
Question 1
Type: MCMA
A patient’s peripheral intravenous catheter has infiltrated several times during an 8-hour shift. The nurse realizes that the patient needs a central venous access device. Which intravascular devices could a properly trained nurse insert under the guidelines of the infusion nursing standards of practice?
Note: Credit will be given only if all correct choices and no incorrect choices are selected.
Standard Text: Select all that apply.
Correct Answer: 2,5
Rationale 1: A triple-lumen catheter is inserted by a physician.
Rationale 2: This catheter can be inserted by nurses educated and skilled in the procedure.
Rationale 3: A tunneled noncuffed catheter is used for long-term therapy and requires an operative procedure for insertion.
Rationale 4: An implanted port is used for long-term therapy and requires an operative procedure for insertion.
Rationale 5: A midline catheter can be inserted by nurses educated and skilled in the procedure.
Global Rationale:
Cognitive Level: Applying
Client Need: Physiological Integrity
Client Need Sub: Pharmacological and Parenteral Therapies
Nursing/Integrated Concepts: Nursing Process: Planning
Learning Outcome: 16-1
Question 2
Type: MCSA
Which nursing diagnosis would explain the purpose of using a self-sheathing stylet catheter?
Correct Answer: 2
Rationale 1: Using a self-sheathing stylet catheter does not improve therapy for fluid volume deficit.
Rationale 2: Risk for Injury is the nursing diagnosis that explains the purpose of the self-sheathing catheter. It is engineered with a safety mechanism that encases the needle in a protective chamber upon removal from the inserted catheter, thus preventing a needle-stick injury.
Rationale 3: The use of a self-sheathing stylet catheter is not related to nutritional status.
Rationale 4: The self-sheathing stylet catheter does not prevent infection.
Global Rationale:
Cognitive Level: Applying
Client Need: Physiological Integrity
Client Need Sub: Pharmacological and Parenteral Therapies
Nursing/Integrated Concepts: Nursing Process: Planning
Learning Outcome: 16-1
Question 3
Type: MCSA
The nurse is preparing to discharge a patient after infusing chemotherapy through an implanted port. What instructions for port care would the nurse provide?
Correct Answer: 4
Rationale 1: Use of a nonadhering dressing is not recommended.
Rationale 2: There is no need to use a sterile dressing.
Rationale 3: Bandaging is not necessary.
Rationale 4: No dressings are necessary because the port is completely under the skin.
Global Rationale:
Cognitive Level: Applying
Client Need: Physiological Integrity
Client Need Sub: Pharmacological and Parenteral Therapies
Nursing/Integrated Concepts: Nursing Process: Implementation
Learning Outcome: 16-3
Question 4
Type: MCSA
A patient receiving peripheral intravenous therapy is mobile but having difficulty maneuvering the intravenous infusion pump. The nurse would choose which add-on device to allow greater mobility for the patient?
Correct Answer: 2
Rationale 1: A multiflow adapter is used for the administration of two or more infusates simultaneously and does not increase tubing length.
Rationale 2: An extension set is a device that adds length to the existing administration set and allows the patient to move more freely without having to push the intravenous pump.
Rationale 3: A stopcock is used to direct flow of an infusate and would not increase tubing length.
Rationale 4: A filter device provides sterility to the infused parenteral medication or solution but does not increase the tubing length.
Global Rationale:
Cognitive Level: Applying
Client Need: Physiological Integrity
Client Need Sub: Pharmacological and Parenteral Therapies
Nursing/Integrated Concepts: Nursing Process: Implementation
Learning Outcome: 16-3
$200.00 Original price was: $200.00.$150.00Current price is: $150.00.
$40.00 Original price was: $40.00.$20.00Current price is: $20.00.
$100.00 Original price was: $100.00.$75.00Current price is: $75.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
511 SW 10th Ave 1206, Portland, OR, United States