Chapter 16: Pulmonary Therapeutic Management
Complete Chapter Questions With Answers
Sample Questions Are Posted Below
MULTIPLE CHOICE
| a. | PaO2 of 80 mm Hg |
| b. | PaCO2 of 35 mm Hg |
| c. | HCO3− of 24 mEq |
| d. | SaO2 of 87% |
ANS: D
The amount of oxygen administered depends on the pathophysiologic mechanisms affecting the patient’s oxygenation status. In most cases, the amount required should provide an arterial partial pressure of oxygen (PaO2) of greater than 60 mm Hg or an arterial hemoglobin saturation (SaO2) of greater than 90% during both rest and exercise.
| a. | Nonrebreathing mask |
| b. | Nasal cannula |
| c. | Partial rebreathing mask |
| d. | Simple mask |
ANS: A
With an FiO2 of 55% to 70%, a nonrebreathing mask with a tight seal over the face can deliver 90% to 100% oxygen. It is used in emergencies and short-term therapy requiring moderate to high FiO2.
| a. | simple mask. |
| b. | nonrebreathing circuit (closed). |
| c. | air-entrainment mask. |
| d. | nonrebreathing mask. |
ANS: B
The most reliable and accurate means of delivering a prescribed concentration of oxygen is through the use of a nonrebreathing circuit (closed).
| a. | oxygen toxicity. |
| b. | absorption atelectasis. |
| c. | carbon dioxide retention. |
| d. | pneumothorax. |
ANS: C
Deoxygenated hemoglobin carries more CO2 compared with oxygenated hemoglobin. Administration of oxygen increases the proportion of oxygenated hemoglobin, which causes increased release of CO2 at the lung level. Because of the risk of CO2 accumulation, all patients who are chronically hypercapnic require careful low-flow oxygen administration.
| a. | measure from the tip of the nose to the ear lobe. |
| b. | measure from the mouth to the ear lobe. |
| c. | measure from the tip of the nose to the middle of the trachea. |
| d. | measure the airway from the corner of the patient’s mouth to the angle of the jaw. |
ANS: D
An oropharyngeal airway’s proper size is selected by holding the airway against the side of the patient’s face and ensuring that it extends from the corner of the mouth to the angle of the jaw. If the airway is improperly sized, it will occlude the airway. Nasopharyngeal airways are measured by holding the tube against the side of the patient’s face and ensuring that it extends from the tip of the nose to the ear lobe.
$40.00 Original price was: $40.00.$20.00Current price is: $20.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$25.00 Original price was: $25.00.$15.00Current price is: $15.00.
$30.00 Original price was: $30.00.$20.00Current price is: $20.00.
$90.00 Original price was: $90.00.$60.00Current price is: $60.00.
$39.99 Original price was: $39.99.$19.99Current price is: $19.99.
511 SW 10th Ave 1206, Portland, OR, United States